UPS for industrial applications: How to choose the best quality systems?

Today’s industrial plants are less susceptible to failure than the industry of the past. The new plant has variable frequency drives (VFDs), computer robots, and more complicated computer-controlled processes like 3D printing. Accordingly, the necessity for high-quality power systems has become more important than ever. Below, find out how to settle on the simplest power systems for your industrial facility, including specific products, factors to think about , and more.

Which power backup system do i select for my industrial facility?
The answer to the present question depends on what sort of processes you’ve got . And in many cases, there’s a 2- or 3-part answer. Many industrial facilities require a computer processing component, the physical manufacturing component, then a further cooling or fan component. the ultimate choice of the proper power solution depends on which of those components you would like to copy .

Visit also: UPS system for Industry

Determining the simplest UPS type for your facility.
A traditional UPS system, originally designed for data centers, is compatible to support computer processes that are integrated into the manufacturing process. However, it’s unable of supporting mechanical and physical process loads or high inrush loads like cooling systems. a mixture of systems is required to support all loads deemed critical within the facility.

You can choose between three categories of investors:

– Traditional IGBT Data Center Inverter – Insulated gate bipolar solid-state inverter system is that the standard for today’s data center inverter systems. It offers a smaller footprint than its predecessor “transformer-based UPS”. it’s more efficient and emits less heat. Therefore, your traditional UPS system solution will use this technology. it’s specially design for IT loads.

– Traditional IGBT Data Center Inverter – Insulated gate bipolar solid-state inverter system is that the standard for today’s data center inverter systems. It requires less space than its predecessor, the “transformer-based UPS”. it’s more efficient and emits less heat. Therefore, your traditional UPS system solution will use this technology. it’s specially design for IT loads.

– Traditional IGBT Data Center Inverter – Insulated gate bipolar solid-state inverter system is that the standard for today’s data center inverter systems. It requires less space than its predecessor, the “transformer-based UPS”. it’s more efficient and emits less heat. Therefore, your traditional UPS system solution will use this technology. it’s specially design for IT loads.

Sizing, planning, and installing industrial systems
How do I size an industrial UPS system?
Sizing an industrial UPS system depends on several components:

available electric power at your facility.
load characteristics of the supporting equipment.
growth projection for the supported loads to satisfy future demand.
For several reasons, you ought to avoid “undersizing” or sizing a system too on the brink of the dimensions of the supported loads. All systems must be oversized to a point . for instance , if you select a UPS that’s too on the brink of the dimensions of the hundreds it supports, your system will run near full capacity, which may put unnecessary stress on equipment and shorten the lifetime of the system. Proper load analysis, full load support, and therefore the dynamic nature of the hundreds all contribute to a sizing decision.

How do I plan an industrial UPS system?
The planning process includes an analysis of the space, the situation of the electrical system, and the way the system will distribute support to the protected loads.

In terms of location, there are several ways to put in your UPS. you’ll install an area UPS system directly on the equipment you would like to guard . Another method is you’ll also install a bigger system at the facility distribution site. you’ll size an industrial UPS system to support your entire facility at the utility entrance. this may offer you the simplest value for your money and permit you to power all the hundreds within the facility.

Installation of an industrial UPS system
A licensed electrical contractor is required to style the installation and install the properly sized distribution breakers upstream of the system. it’s recommended to put in a maintenance bypass system to be ready to bypass the UPS system just in case of maintenance, repair, or replacement without interrupting the supported loads. The environment should consider because the UPS and batteries require an appropriate temperature home in the power . In some cases, a separate enclosure or room is build to supply cooling and clean air. To separate the UPS system and batteries from the economic environment, outdoor enclosures are suitable and available.